Actisense PRO-BUF2 Intelligent Type NMEA Buffer
£449.00
Exc VAT
Actisense PRO-BUF2 Intelligent Type NMEA Buffer
The PRO-BUF-2 is rugged, with a stainless steel housing, and provides isolation on all inputs and outputs. With two NMEA 0183 inputs, twelve NMEA 0183 outputs, a bi-directional serial port and an Ethernet port. The PRO-BUF-2 is a perfect solution for larger leisure vessels, commercial shipping and is a great addition for systems that require type-approved devices. The PRO-BUF-2 is designed to suit the majority of NMEA 0183 systems and ready to go ‘out of the box’ by simply hard-wiring the two-mode inputs as required.
- The Intelligent NMEA 0183 Buffer manually configurable basic modes of operation include variations of buffer modes, intelligent auto-switch, and combine modes.
- For all other configurations, leaving the mode inputs floating selects the ‘User Configuration Mode’. The web-based configuration tool allows full customisation of the PRO-BUF-2, and is compatible across all popular Operating Systems. Using the web-based configuration tool allows for fine-tuning of the data available on each output.
- To make installation quick and simple the PROBUF-2 features 2-part pluggable connectors that allow the use of screw terminals*, and a professional DIN Rail mounting system (DIN Rail not included). The device can also be mounted directly to the bulkhead.
- Helpful LEDs indicate power, data in, data out, and the alarm status to aid diagnostics.
- Data statistics and load indication via the web tool provide a real-time view of data.
- 5 YEAR GUARANTEE.
Features
- 2 Opto-Isolated inputs
- 12 ISO-Drive NMEA 0183 outputs
- Ethernet Port
- Flexible operating modes
- Automatic Baud Rate matching on inputs
- Alarm output options
- Web based configuration tool
- Diagnostic LEDs
- Advanced Data Filtering and Routing
- 2 virtual Autoswitch modules
- Data statistics and load indication via web tool
- Designed for 12 / 24 Volt supply
- Future proofing with easily upgradable firmware
- 2-part pluggable connector system
- Stainless Steel Housing with DIN rail mount option
- Type Approved
Benefits
- Flexible configuration options to buffer autoswitch or combine NMEA data
- ISO-Drive separates the Listener from the Talker to protect both the PRO-BUF and each connected device.
- Fast bi-directional data connection to a monitor and control software application
- PRO-BUF can be configured using any web browser on any Operating system
- Works out-of-the-box without configuration for basic installations, or can be easily user configured as required
- Relay output is compatible with on-board alarm systems and NMEA Alarm sentence can be displayed and actioned on an MFD
- Easy to access via network, doesn’t require the device to be moved or have a serial connection to the PC.
- Quick visual check gives the user confidence that each input and output is passing data
- Features can be utilised to fine tune data, avoiding data overloads on the outputs and connected listeners
- Allows automatic data priority selection between two devices of the same type of data (e.g. GPS)
- Shows the NMEA 0183 on each I/O Port, and how frequently it arrives, great for low level diagnostics
- Allows use on large vessel 24V DC power supplies systems
- Additional features in future firmware revisions are accessed using a simple update process via Actisense Toolkit over Ethernet
- Fast installations and supports both screw and screwless terminal types. Ideal for quick diagnostic swapping
- Increased durability, ease of installation and high performance
- Can be installed on vessels governed by Class Society Rules
Technical
Power Supply
- Input Supply Voltage – 9 to 35 V DC
- Input Supply Current – 325mA max @ 12V DC (all outputs @ full drive into 100 ohm loads)
- Input Protection – Continuous reverse polarity, transient overvoltage and ESD protection
- Power Indicator LED, Blue – indicates unit is functioning correctly
- Input Supply Connector Pluggable 2-way screw terminal, 5.08mm pitch
NMEA 0183 Port – Listener & Talker
- Number of Listener / Input Ports – 2 isolated NMEA 0183 Listeners
- Number of Talker / Output Ports – 12 isolated NMEA 0183 Talkers
- Compatibility – Fully NMEA 0183, RS422 & RS232 compatible. RS485 Listener compatible
- Speed / baud rate – 4800 to 38400 bps
- Talker Output Voltage Drive – >= 2.2V (differential) into 100 ohm
- Talker Output Current Drive – 20 mA maximum per output
- Talker Output Protection – Short circuit and ESD
- Talker Data Indicator – LED, Orange (Flashes at data rate)
- Listener Input Voltage Tolerance – -15 V to +15 V continuous, -35 V to +35 V short term (< 1 second)
- Listener Input Protection – Current limited, overdrive protection to 40 VDC and ESD protection
- Listener Data Indicator – LED, Green (Flashes to indicate valid input)
- Connectors – Pluggable 2/3-way screw terminals, 5.08mm pitch
Serial Port
- Compatibility – RS422 & RS232 compatible. RS485 Listener compatible
- Speed / baud rate – 4800 to 115200 bps
- Output Voltage Drive – >= 2.1V (differential) into 100 ohm
- Output Current Drive – 20 mA max.
- Output Protection – Short circuit and ESD
- Input Voltage Tolerance -15 V to +15 V continuous, -35 V to +35 V short term (< 1 second)
- Input Protection = Current limited, overdrive protection to 40 VDC and ESD protection
- Data Indicators – LED’s: Green = Receive, Orange = Transmit
- Connectors – Pluggable 3-way screw terminals, 5.08mm pitch
Ethernet Port
- Host Interface – 10/100BaseT, automatic polarity detection
- Supported Protocols – TCP/IP for configuration and firmware updating
- TCP/IP and UDP for NMEA 0183 comms
- Indicators – Green = Link/Activity, Yellow = 100 Mbps
- Connector – RJ45
Isolation
- NMEA 0183 Listener – OPTO-Isolated, Hi-Pot tested to 1000V
- NMEA 0183 Talker – Uses IsoDriveTM, Hi-Pot tested to 1000V
- Serial Port – Uses IsoDriveTM, Hi-Pot tested to 1000V
- Alarm Relay – Hi-Pot tested to 1000V
- Ethernet Port – 2kV for 60s
Mode Inputs
- Input Voltage Range – 0 to 35V DC
- Protection – Transient overvoltage and ESD protection
- Connectors – Pluggable 2-way screw terminals, 5.08mm pitch
Alarm Output
- Contacts – Common, Normally Open and Normally Closed
- Alarm Indicator – LED, Red indicates a valid alarm condition
- Contact Ratings – 35VAC / 50VDC
- Connectors – Pluggable 3-way screw terminals, 5.08mm pitch
Mechanical
- Housing Material – 316 Stainless Steel
- Dimensions – 210mm (W) x 128mm (H) x 27mm (D)
- Weight – 530g
- Mounting – Bulkhead mount or DIN rail mount (DIN kit 1)
Approvals and Certifications
- EMC – IEC 60945:2002-08, DNVGL-CG-0339:2019 & IACS UR E10 Rev7
- Compass Safe Distance – 750mm
- Type Approval Certificate – RINA
- Operating Temperature – -25 to +70°C
- Storage Temperature – -40 to +85°C
- Relative Humidity (RH) – 95% @ 55°C
- Environmental Protection – IP40
- Guarantee – 5 Years