ONWA KC2W Bidirectional Converter
£94.95
Exc VAT
ONWA KC-2W Bidirectional Converter
Converts NMEA 0183 Sentences to N2K PGNs and the other way around. Taking the power from the N2K network therefore no external power supply is required.
- Configurable NMEA0183 Baudrate
- Opto-isolated on N2K CAN bus
- Opto-isolated on NMEA0183 input
- Auto detect NMEA0183 baudrate and supported sentences
- Supports fuel flow sensor
- Firmware upgrade and NMEA0183 Output baudrate configuration by supplied PC Software.
- Plug and Play Installation.
Upgrades Available:
1
For Further Information Please Contact the office - Click Here
Specification
Power supply: (N2K Port) Electrical: 9 ~ 30VDC Current drain: 50mA at 12VDC Protection: over-voltage, power transient and accidental reverse polarity protection
N2K Port (IEC61162-3)
Supported PGNs: 126992 , 127237, 127245, 127488, 127250 , 127251 , 127258 , 127489, 128259 , 128267 , 128275 , 129025 , 129026 , 129029 , 129033 , 129038, 129039, 129040, 129044 , 129283 , 129284 , 129291 , 129539 , 129540 ,129793 , 129794 , 129798 , 129809 , 129810, 130306 , 130310 , 130311 , 130312 , 130578
Electrical: Opto-isolated on N2K Can bus
Speed/baudrate:
Connector: M12 male / Cable length: 1.2 meter / Factory default: All above supported PGNs are enabled
Electrical: Opto-isolated on N2K Can bus
Speed/baudrate:
Connector: M12 male / Cable length: 1.2 meter / Factory default: All above supported PGNs are enabled
NMEA0183 Port(IEC61162-1)
Supported Sentences: APB, BOD, BWC, BWW, DBT, DPT, DTM, GGA, GLL, GSA, GSV, HDG, HDM, HDT, MDA, MTW, MWD, MWV, RMC, ROT, RSA, VDM, VDO, VDR, VHW, VLW, VTG, XDR, XTE, ZDA
Electrical: Output: RS232/ Input: RS232 opto-isolated
Baudrate: Output: Configurable (factory default 38400) / Input: Auto detect (up to 115200)
Factory default: All above supported NMEA0183 are enabled
Electrical: Output: RS232/ Input: RS232 opto-isolated
Baudrate: Output: Configurable (factory default 38400) / Input: Auto detect (up to 115200)
Factory default: All above supported NMEA0183 are enabled
Fuel Port: Input signal: TTL
Output:N2K PGN: 127489/ NMEA0183 sentence: XDR
Environmental Conditions: Working temperature: -20°C to +55°C / Humidity: 93% ±3% on 40°C / Waterproofing:IPX67
Equipment List – Standard
KC-2W main unit.
Attached with 1.2 meters cable with M12 male 5 pins connector (N2K) on one end
Attached with 1.2 meters cable with open wires(NMEA0183)) on the other end
Mounting screws X 4 pcs Manual (quick installation manual)
Dimensions
1 in stock (can be backordered)